When a run is longer than Cat6 can carry, when the network has to cross to another building, or when switches need 10-gigabit links between closets, fiber is the answer. Harold Ragan Communications installs fiber backbones and building-to-building fiber links, terminates them in proper enclosures, labels both ends, and tests every strand before we call it done.
Most drops to desks, phones, cameras and access points should stay Cat6. Fiber earns its place on the links that tie the network together.
Copper Ethernet has a hard limit: 100 meters, or 328 feet, per run. In a large warehouse, a plant, a school wing or an office building with closets on different floors, the run from the main network closet to the far closet is often longer than that. Fiber carries the same network for thousands of feet, at 10 gigabits and beyond, and it is not affected by the motors, welders and electrical noise that cause trouble for copper on an industrial floor.
Fiber is also the right way to leave the building. A copper run between two buildings is exposed to lightning and ground differences; fiber carries no electricity, so a strike near the shop does not travel back into the main building's switches.
We do. Harold Ragan Communications is the networking and telecommunications division of Harold Ragan CodeWorks, based in Lowell. Because we also install the Cat6 cabling, the switches and the Wi-Fi, the fiber is planned as part of the whole network, not as a separate trade.
Link the main network closet to IDF closets across a warehouse, a plant or a multi-floor office when the distance is beyond Cat6.
Connect a second warehouse, a shop, a yard office or a separate office building through underground conduit.
Give core and edge switches fast uplinks so cameras, Wi-Fi and busy departments are not squeezed through one copper port.
Run network links past motors, welders and heavy electrical gear without the interference copper picks up.
Tie several buildings into one network with a central closet, for churches, schools, camps and multi-building businesses.
Plan backbone pathways and conduit with your general contractor before the walls and slab are finished.
Clean pathways, proper enclosures, labels on both ends, and test results you keep.
Single-mode (OS2) is our usual choice between buildings and on long runs, because it has the most room for future speeds. Multimode (OM3 or OM4) works well for shorter backbones inside one building. The equipment on each end, usually SFP or SFP+ modules in your managed switches, is matched to the fiber type.
Inside, fiber runs in the correct fire rating for the space, on its own supports or in innerduct so it is protected from the rest of the cabling. Between buildings, outdoor-rated cable goes through underground conduit sized and routed for it, with pull points where the path turns.
Each end lands in a rack-mount or wall-mount fiber enclosure with LC connectors, so patching to a switch is a clean jumper rather than a cable hanging out of the wall. Spare strands are terminated too, ready for the next need.
Every strand is tested with an optical light source and power meter, and you get a loss report for each one. Labels on both ends match the documentation, the same standard we hold every Cat6 run to.
We design the route and conduit and coordinate the trench with your general contractor or an excavation contractor. Where trenching is not practical, a wireless bridge may be the better answer, and we will say so.
We walk both ends, measure the route, check existing conduit and closets, and look at what the link needs to carry.
You get a fixed quote naming the fiber type and strand count, the route, the enclosures and the switch modules.
We pull the fiber through its pathway, terminate it in enclosures at both ends and connect it to the network.
Every strand is tested and labeled, and you receive the loss report and a record of the link.
We install fiber across Northwest Arkansas from our Lowell office, and for larger projects in the River Valley, southwest Missouri and northeast Oklahoma.
Cat6 Ethernet is limited to 100 meters (328 feet) per run. Fiber is the answer when a closet-to-closet run is longer than that, when a link leaves the building or runs between buildings, when it passes near heavy electrical equipment, or when you want 10-gigabit or faster capacity between switches.
Single-mode (OS2) is the usual choice for building-to-building links and long runs, and it has the most headroom for future speeds. Multimode (OM3/OM4) is common for shorter backbones inside one building. We recommend one at the site visit based on distance and the equipment on each end.
Fiber is the stronger link: multi-gigabit capacity, no line-of-sight issues and nothing for weather or summer leaves to affect. A wireless bridge is faster and cheaper to put in when trenching is expensive or impractical. We install both and will tell you which one fits your property.
We plan the route and the conduit, and coordinate the trench with your general contractor or an excavation contractor. Once the conduit is in, we install, terminate and test the fiber.
Every strand is tested with an optical light source and power meter after installation, and you get a loss report for each one, along with labels on both ends that match the documentation.
Yes. Most business-grade switches and gateways take SFP or SFP+ fiber modules, whatever the brand, so a fiber backbone or building link plugs directly into your network. We match the modules to the fiber and the equipment on each end.
Tell us what needs to be connected and roughly how far apart the two ends are. We will tell you whether fiber, Cat6 or a wireless bridge fits, and give you a fixed quote after a site visit. Harold Ragan Communications — the networking division of Harold Ragan CodeWorks.